通比牛牛

Smart electricity

He Yuan, electrical management industry

Intelligent power distribution, energy efficiency management, industrial automation—station service provider

National Service Hotline:

400-616-3226

Smart electricity
Location: Home > Products > Electrical Safety > Electrical Fire Monitoring System
  • 电气火灾监控系统
    Electrical fire monitoring system
    HYEF electrical fire monitoring system is a product designed and developed according to the requirements of GB14287-2014 "Electrical Fire Monitoring System" to ensure that all functions such as alarm, monitoring, control, and management can be realized.
    Product Details



    Recommended Products:

    ,是指通过物联网技术对引发电气火灾的主要因素进行实时的数据跟踪与统计分析,实时发现安全隐患,经云平台大数据分析,通过手机APP或者短信等方式,即时向安全管理人员发送预警信息,实现“防患于未然”的目的。 The intelligent power safety supervision service system refers to the real-time data tracking and statistical analysis of the main factors that cause electrical fires through the Internet of Things technology, real-time detection of hidden safety hazards, big cloud data analysis through cloud platforms, and mobile phone APP or SMS, etc. Method to send early-warning information to security managers in real time to achieve the purpose of "preventing problems before they occur".


    Electrical fire monitoring System Overview


    The electrical fire monitoring system is installed in the fire control room and consists of electrical fire monitoring equipment, residual current electrical fire detectors, temperature measuring electrical fire detectors, residual current transformers, temperature sensors, and so on. HYEY electrical fire monitoring system is a product designed and developed in accordance with the requirements of GB14287-2014 "Electrical Fire Monitoring System" to ensure that all functions such as alarm, monitoring, control, and management can be realized.


    The system supports MODBUS higher-level communication protocol, and can communicate with third-party higher-level control systems. It supports networking with graphic display devices and networking between multiple controllers to meet various engineering needs.


    Topology diagram of electrical fire monitoring system

    Technical standards and specifications
    The design, manufacture, inspection and supply of electrical fire monitoring systems must meet the requirements of relevant national and industry codes and standards. At the same time, they must meet the following technical specifications and the following standards:
    The design and application of electrical fire monitoring systems should meet the following standards and specifications:
    GB50116-2013 "Code for Design of Automatic Fire Alarm System"
    GB50016-2014 "Code for Fire Protection of Building Design"
    GB14287.1-2014 "Electrical Fire Monitoring Equipment"
    GB14287.2-2014 "Residual Current Electrical Fire Monitoring Detector"
    GB14287.3-2014 "Temperature measuring electrical fire monitoring detector"
    DB37 / T 2122-2012 Shandong Province "Code for Design, Construction and Acceptance of Electrical Fire Monitoring System"
    The electrical fire series products provided by the electrical fire monitoring system are guaranteed to meet the newly issued standards and specifications of the People's Republic of China before acceptance.
    Standards and norms conflict resolution:
    Conflicts between standards and specifications: Adopt strict standards and specifications.
    Conflicts between standards, specifications, and technical requirements: Adopt strict requirements.

    Function description


    When the system detects that the residual current or temperature of the power distribution line is abnormal and reaches the alarm set value, the detector transmits the alarm information to the electrical fire monitoring equipment through two buses, and the monitoring equipment performs an audible and visual alarm within a specified time.The interface The alarm loop information is displayed in real time and printed out, so as to remind the staff on duty to check the danger situation.



    System advantages
    Ultra-low power consumption: The power consumption of the detector is less than 0.02W. Each circuit supports node loading within 200. The standard 1.5m㎡ twisted-pair communication distance is 1500 meters at full load.
    Low cost: The system is upgraded to TBUS two-bus communication, the system is more stable, and the signal and power supply share two wires, saving wiring costs.
    Easy commissioning: Each channel of the combined electrical fire monitoring detector supports the monitoring of temperature, residual current, and over-current.

     Large monitoring range: 400: 1, 2000: 1, 10000: 1 transformers can be connected, no separate customization is required.


    Application area
    Can be used in petrochemical, industrial base, rail transportation, civil construction, public buildings and other fields.

    service quality
     24-hour service: The professional pre-sales and after-sales service team responds to related issues raised by customers within 2 hours and gives solutions within 24 hours;
     Free upgrade: The company provides product software upgrade for free;
     Various aspects of training: Our company arranges relevant dispatchers to train the system to ensure that operators can independently operate and maintain the system;
     Two-year warranty: During the warranty period, all repairs or replacements are free of charge except for damage caused by human factors. After the warranty period, our company will continue to provide users with repair and maintenance services through door-to-door or return to the factory. It only charges the cost of labor and provides product software upgrade services for free.
    The product-related spare parts provided by our company are stocked in Jinan. The company is committed to providing long-term supply and on-site service to ensure that buyers can purchase the spare parts and wearing parts required by the goods in a timely manner.

     Our company can provide a complete set of information related to management, operation and maintenance to ensure the normal operation of the supplied products, including but not limited to the following information:


    Serial number

    Delivery document name

    1

    "Instruction Manual"

    2

    "Certificate of conformity"

    3

    装箱清单》 Packing List

    4

    产品接线图》 " Product wiring diagram"

    5

    The products supplied must have valid inspection reports from relevant national departments

    Leave message

    Recommended by engineer He Yuan
    • Similar products recommended
    • related product recommendation
    • Recommended products
    HYEF-R剩余电流式电气火灾监控探测器
    XE03系列剩余电流互感器
    HYEF-T2测温式电气火灾监控探测器
    HYEF-R剩余电流式电气火灾监控探测器
    XE03系列剩余电流互感器
    HYEF-T2测温式电气火灾监控探测器
    Engineering case
    Copyright 2017 鲁 ICP 备 16050284 号 -1 Copyright: Heyuan Intelligent Technology Co., Ltd.
    Address: Sales Hotline, 7th Floor, Building 1, Aosheng Building, No. 1166, Xinjing Street, High-tech Zone, Jinan